A person was pulled to the deck of the moonpool platform.

What happened?

During moonpool preparations for running the a tool in the hole, the crane whip line was being lowered to deck under supervision of the deck supervisor. A third-party contract worker walked over the moonpool landing area with a fall arrestor connected to his harness. The swinging whip line contacted the wire of the fall arrestor, pulling the person to the deck of the moonpool platform. No injuries were reported by the person at the time of the incident.

Person pulled to deck by fall arrest harness

Showing person in green helmet before incident. His fall arrest line illustrated in red

Person pulled to deck by fall arrest harness

Showing person in green helmet pulled to the deck and crane block at top left

What went wrong?

  • Lack of communication between the deck supervisor and the third-party contract worker.
  • The third-party contract worker did not receive any instruction to stand clear during the operation.
  • The whip line was lowered into area while operations were ongoing.
  • The workers’ fall arrest was connected to the opposite side of the moonpool.
  • There was a lack of situational and operational awareness – the person placed themselves in the line of fire.
  • Parallel or simultaneous activities were being conducted.

What was the cause?

  • Our member noted that:
  • The immediate causes were:
    • Inadequate preparations/planning.
  • The root causes were:
    • Inadequate discipline.
    • Inadequate supervision.
    • Inadequate reinforcement of proper behaviour.

Lessons

  • Improve communication between personnel working together (deck crew and third-party contractors).
  • Use taglines particularly in rough conditions or in congested areas.
  • All personnel should remain clear when whip line is being lowered in the area.
  • Take care to consider the safest connection point for your safety harness.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.