Skip to content

Oil leakage from vessel crane onto quayside

What happened

A hydraulic pipe burst causing an oil leak. The incident occurred when a vessel was alongside retrieving anchor handling chains from chain lockers to the main deck. This operation had been ongoing for nine hours at the time of the incident. There was little or no adequate lighting on the quayside.

During movement of the vessel’s crane, the Bosun observed the wet stains of leaking hydraulic oil which had spilled on the surface of the quayside platform gratings and onto the concrete. The job was stopped, and deck crew started searching for the leakage source. The crew inspected the quayside to check for spillage.

Inspection taking place in poor light conditions – missing the leak
View of the spillage area in the morning

What went wrong

  • During inspection it was discovered that there was a rupture in a hydraulic hose of the vessel crane.
  • Though a search for leakage to the quay took place, poor lighting meant that the crew failed to notice any sign of oil spillage;
  • There was a lack of compliance with incident reporting requirements – this incident was initially left unreported by the vessel crew;
  • It was subsequently discovered that the crew were unaware of the requirements to report any releases or spills to the environment.

What was done next

  • Ensure crew properly understand the need to report any releases or spills to the environment;
  • Ensure planned maintenance of hydraulic hoses – regular visual inspection to be instituted, and regular and immediate renewal of hoses based on their physical condition.

Members may wish to refer to

Safety Event

Published: 23 November 2022
Download: IMCA SF 26/22

Relevant life-saving rules:
IMCA Safety Flashes
Submit a Report

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of all. The effectiveness of the IMCA Safety Flash system depends on Members sharing information and so avoiding repeat incidents. Please consider adding [email protected] to your internal distribution list for safety alerts or manually submitting information on incidents you consider may be relevant. All information is anonymised or sanitised, as appropriate.

IMCA’s store terms and conditions (https://www.imca-int.com/legal-notices/terms/) apply to all downloads from IMCA’s website, including this document.

IMCA makes every effort to ensure the accuracy and reliability of the data contained in the documents it publishes, but IMCA shall not be liable for any guidance and/or recommendation and/or statement herein contained. The information contained in this document does not fulfil or replace any individual’s or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.