MSF: Two dropped object incidents

  • Safety Flash
  • Published on 12 February 2024
  • Generated on 11 April 2026
  • IMCA SF 03/24
  • 3 minute read

While pulling a pin out, the metal wedge in place was dislodged and fell between the gangway components, 13m to the deck below.

Incident 1 – dropped metal wedge

A pin was required to be pulled on a hinge system for the dynamic gangway system on a W2W (walk-to-work) vessel. As part of this task metal wedges were used to hold some of the gangway components in place. The job of pulling the pins was not going as expected due to space limitations, the effects of surface corrosion on the pins and the chosen method of pulling the pins. While pulling the pin out, the metal wedge in place was dislodged and fell between the gangway components, 13m to the deck below.  No-one was underneath the gangway at the time. MSF Safety Alert 23-17.

Dropped object incidents
Dropped object incidents

What went wrong?

  • The metal wedges did not have a place to secure a tethering device.
  • The method chosen to pull the pin was not optimal.
  • Not all the tools could be secured from dropping and there was no collective dropped object arrest system to catch smaller tools or items.
  • The aft area around the gangway was not fenced off and personnel could have walked underneath the drop zone.
  • Simultaneous operations were taking place in the area on deck around the gangway and there was a risk of someone accidentally walking into the DROPS zone.

Actions taken

  • Modified the metal wedges to accept a tethering device.
  • Investigated how a collective dropped object arrest system such as a net could be installed under the gangway for future work.
  • Identified an optimal solution for pulling the pins on gangway.
  • Improved guidance and training for personnel on barriering-off areas in a DROPS zone.    

Incident 2 – Dropped Lightning Rod

A lighting rod conductor mounted on top of a dynamic gangway tower for a Walk-To-Walk vessel was found lying on the deck below the tower. No personnel onboard the vessel observed or heard the object fall. 

The potential for serious injury existed due to: 

  • The location of the dropped area (deck is frequented by personnel)
  • The weight of the object (1.5kg) and the distance it fell (26m).

What went wrong

There was no obvious damage to the rod or fittings, it is assumed that the fittings loosened / unscrewed over time. The incident presents immediate causes such as:

  • Impact of rough or bad weather on the rod securing connections.
  • Lack of inspection/maintenance on the securing of the rod.
  • Design deficiency in terms of a secondary securing mechanism for the rod.

Actions taken

  • Ensure checking of lightning rod conductor fittings and other similar fittings such as lights, cameras, wind sensors etc are included in planned maintenance schedule.
  • Install a secondary securing mechanism where necessary.  

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.