Chain hoist paid out unsupervised near running main engine

  • Safety Flash
  • Published on 9 January 2024
  • Generated on 11 April 2026
  • IMCA SF 01/24
  • 3 minute read

Motorman observed the hoist’s chain with hook to have “paid out” fully and created a dangerous condition near to main engine

What happened?

An electric chain hoist on the beam above one of the main engines in a vessel, was left unattended after use. The chain hook paid out and coiled the chain onto the running main engine close to the generator drive shaft. The incident occurred when the chain hoist was being used to lower spare parts required for maintenance in the engine room. Two lifts took place above the running main engine. After their completion, the chain block was lifted into its highest position.

Later on, during routine rounds, the motorman observed the hoist’s chain with hook to have “paid out” fully and created a dangerous condition near to main engine no.3. The chain was made safe and then removed from service for inspection.

Chain hoist paid out unsupervised near running main engine

What went wrong?

  • The push button for “pay-out” on the pendant controller for the electric winch, was found to be defective, resulting in hoist being given a continuous payout command;
  • The operator of the hoist was aware that the chain continued to pay out after push button was released in the first instance, but after repeated operations of the button assumed the intermittently ‘sticky’ button had been freed and that the equipment was safe for use;
  • The emergency stop button was not engaged after use which enabled the faulty button to allow the hoist to continue uncontrolled pay out;
  • The hoist, although paid in, was not stowed and secured as per the routine working practice onboard;
  • As a result of the continuous payout operation, the motor was found to be burnt out and will require to be replaced.

Actions

  • Ensure crew are familiar with original equipment manufacturer (OEM) operator manuals for all hoist equipment before use;
  • Review control function of hoists and where no designated isolation switch is in place, determine a safe, and practical means of safe isolation.
  • Ensure visual and function tests for lifting equipment are conducted with defects/ damage corrected before use.
  • Review whether hoists can be safely used parallel to or in close proximity to running machinery.
  • Review frequency of planned maintenance for electrically driven, operated and controlled lifting hoists, to minimize risk of control functions degrading due to infrequent usage, and to ensure an annual function test is completed.

Latest Safety Flashes:

MAIB: Sinking of tug Biter with loss of two lives

MAIB has published Accident Investigation 17/2024 relating to the girting and capsize of tug Biter with the loss of two lives.

Read more
Dropped object – strop parted over sharp edge

A cylinder was lifted to a height of approximately 6 metres over deck of the vessel, the sharp steel edges of the cylinder cut through the firehose protection and caused the strop to part.

Read more
Person injured when pry bar slipped

A crew member who was applying downward pressure to their pry bar to lift a track, fell towards the deck when the pry bar slipped.

Read more
MSF: High potential near miss during FRC maintenance

The Marine Safety Forum has published Safety Alert 26-01 relating to an incident where there was an unplanned lowering of an FRC to the sea

Read more
BSEE: Crane incident leads to serious facial injuries

BSEE has published Safety Alert 512 relating to a crane incident during well abandonment which led to a worker being struck and suffering serious facial injuries.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.