Carriage of methanol – dangerous goods – without proper certification
- Safety Flash
- Published on 18 June 2024
- Generated on 11 April 2026
- IMCA SF 12/24
- 2 minute read
Jump to:
The vessel which carried out the work was not in possession of a Dangerous Goods Document of Compliance.
What happened?
Methanol was being transported from place to place offshore, without appropriate Dangerous Goods certification. Methanol is very flammable. The incident occurred during the refuelling of a LIDAR buoy at an offshore wind farm. This involved carrying methanol cannisters on board a vessel, recovering the buoy, loading the methanol into the buoy, and redeploying the buoy. The vessel which carried out the work was not in possession of a Dangerous Goods Document of Compliance.
What went wrong?
The vessel had standard FFE/LSA as a workboat but was ill-equipped to carry over 700 litres of methanol.
The principal contractor who hired the vessel did not include carriage of methanol in a Risk Assessment and Method Statement and had cleared the vessel through their own vetting department. The issue was raised internally by the client who recorded it as a High Potential Near Miss given the flammable and toxic properties of methanol.
Further investigation found that that this was “not an isolated incident” and that the use of workboats and smaller vessels to carry Class 3 DG for the purpose of refuelling LIDAR buoys had occurred in the industry with other developers.
What was the cause?
There was no intent to mislead. The root cause seemed to be lack of awareness. Our member noted that amongst certain of their suppliers there was a perceived lack of awareness of the hazards posed by Dangerous Goods and of marine operations in general.
Actions
What lessons were learnt?
- Carriage of Methanol requires a DG DOC (or flag state exemption with certain mitigations in place).
- LIDAR buoys, when fully fuelled, are themselves classed as DG, and as such, ought to be carried only by vessels with DG DOC (as above).
- The offshore renewables industry has not fully appreciated the hazards of marine operations and the carriage of DG. See below, “Members may wish to refer to”.
- Importance of raising awareness within the offshore renewables industry, and also within the maritime industry, to remind vessel owners, vessel crew, charterers (including offshore renewable developers) of the requirements for the carriage of DG cargoes.
Related Safety Flashes
-
IMCA SF 15/15
13 October 2015
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.