Two deaths of military divers
- Safety Flash
- Published on 23 October 2020
- Generated on 22 February 2025
- IMCA SF 30/20
- 3 minute read
Jump to:
A "Crown Censure" is the way in which the UK HSE formally records the decision that, but for Crown immunity, the evidence of a Crown body's (in this case the MoD) failure to comply with health and safety law would have been sufficient to provide a realistic prospect of securing a conviction.
What happened?
Incident 1 - UK
The UK Health and Safety Executive has issued the Ministry of Defence (MoD) with a “Crown Censure” after a military diver died during training. The UK HSE press release, dated 2 September 2020, is found here.
In March 2018, a diver being trained was brought back to surface after he stopped responding to lifeline signals while he was underwater. He was sadly pronounced dead after CPR was performed. He had been on a training course at the National Diving and Activity Centre in Chepstow. The diver and his dive buddy were tasked with attaching a distance line from the base of a shot line to the underwater wreck of a helicopter at a depth of 27m. When he was recovered his cylinders were found to be empty.
The UK HSE served two Crown Improvement Notices relating to the failure to train all army divers how to undertake air endurance calculations and to assess the risk of a diver running out of air.
Julian Tuvey, a HSE inspector who specialises in diving, said: “This was a tragedy for all concerned however just like any other employer, the MoD has a responsibility to reduce dangers to its personnel, as far as they properly can. The scenario of a diver running out of air is a very real risk that needs to managed.”
The Ministry of Defence accepted the Crown Censure and hence admitted breaching its duty under Section 2(1) of the Health and Safety at Work etc. Act 1974 in that they failed to ensure, so far as was reasonably practicable, the health, safety and welfare at work of all its employees, in relation to the risks associated with diving exercises.
Incident 2 - New Zealand
The New Zealand Defence Force was sentenced at the Auckland District Court for health and safety failings following the death of a trainee diver. In March 2019 a group of trainees was taking part in an 18 week advanced diving course. Following a full day of dive exercises, the trainees were undertaking a night dive when one of the trainees was identified as in trouble and pulled unresponsive from the water. The trainee later died as a result of a brain injury due to oxygen deprivation.
Investigation found the exercise went against the Defence Force’s own training standards. It also found trainees were covertly switching their breathing apparatus from nitrox to oxygen mode, which ran the risk of leading to oxygen deprivation. This switching activity was known between trainees but not to their supervisors in the Defence Force.
Further information can be found in the press release here: https://worksafe.govt.nz/about-us/news-and-media/defence-force-sentenced-over-diver-fatality/
IMCA notes: These incidents reinforces IMCA’s published position that self-contained underwater breathing apparatus (SCUBA) has inherent limitations and is not a suitable technique for work covered by the IMCA International Code of Practice for Offshore Diving (IMCA D014).
Members should refer to IMCA D033 Limitations in the Use of SCUBA Offshore.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.