Line of fire near miss during lifting operations

  • Safety Flash
  • Published on 18 December 2023
  • Generated on 30 April 2025
  • IMCA SF 29/23
  • 2 minute read

A member of the deck crew member put themselves in the line of fire during landing of a structure  on the back deck of a vessel.

What happened?

The installation aids (bumper bars) were insufficient to stabilise the load, resulting in the structure being landed narrowly missing the individual, and damaging an adjacent container. 

The bumper bars were a critical barrier for keeping the banksman safe on the walkway but as they were not spaced far enough apart for the structure, they allowed a rotational movement of the load.

Snapshots from CCTV footage of near miss showing swinging load impacting container

Snapshots from CCTV footage of near miss showing swinging load impacting container

What went right?

  • Before landing the structure, the area had been barriered off and non-essential personnel removed from the area.

  • All the containers were checked to ensure no-one was working inside them during the lift.

What went wrong?

  • The individual was focused on landing the structure in a tight space and was relying on the bumper bars to keep him safe in the event of unplanned movement of the structure.

  • Even though the design of the installation aids (bumper bars) was within the vessel’s design code, they were not there to protect people, but there as aids to landing and moving structures around the deck without damage. As they were not designed for personnel protection, the distance between them was not considered.

Actions

  • There was a general misconception that installation aids can be used as personnel protection devices, but this is not their design nor their appropriate use.

  • Moving the counterweight location and bumper bars was seen as an improvement by the vessel team and therefore they did not go through a Management of Change (MOC) process. Even perceived improvements may have negative consequences and need to be managed.

  • Despite all the good work done in pre-job planning, the banksman still put himself in the line of fire. In hindsight, this area should have been a complete no-go zone.

  • Take into account when planning work, the difference between “work as imagined” and work as actually done.

  • Remain aware of your close environment and understand that during lifting activities, the exclusion zone may change.

  • Review tasks where installation aids are being relied on for personnel protection. Should a wider exclusion zone be put in place for these tasks?

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.