MAIB: Worker falls between vessel and quay

  • Safety Flash
  • Published on 13 December 2022
  • Generated on 22 February 2025
  • IMCA SF 28/22
  • 3 minute read

The Marine Accident Investigation Branch Safety Digest 2/2022 includes an incident in which a shore worker fell 8m between vessel and quay, suffering significant injuries.

What happened?

A shore worker boarded a berthed bulk carrier via the gangway to obtain a signature on some paperwork. Because of the falling tide, the gangway was then stowed, its safety net was removed and the crew started to rig an alternative means of safe access and egress. The shore worker returned to the deck with the signed paperwork and was advised by the crew to wait a few minutes for this to be safely prepared for his disembarkation. He was also informed that the gangway was no longer in use for access.

CO climbing down to assist shore worker

Showing the actual rescue of the shore worker

What went wrong?

The shore worker ignored the crew’s direction and walked along the stowed gangway, intending to jump ashore from its lower platform. At the lower platform, the shore worker slipped, lost his balance and fell over 8m into the sea between ship and shore, suffering significant injuries.

What went right

The alarm was raised and emergency services were quick to arrive on scene. Meanwhile, the Chief Officer climbed down the jetty ladder and pulled the shore worker out of the water and safely into a recess just above sea level. From there, the shore worker was evacuated to hospital on a stretcher for treatment of his injuries.

The lessons

  • Procedures: The shore worker was largely responsible for his own injuries. Crew instructions to visitors are not optional advice, and here were ignored!! This accident demonstrates the importance of safe means of access and the importance of managing and, where necessary, directing visitors on board to be safe.
  • Risk: Don’t rush!! Rushing to depart led to a nasty fall into the sea and injuries that required hospital treatment. Although waiting might have seemed tiresome, the short delay to the shore worker’s departure would be nothing compared to the pain and inconvenience he suffered from the fall. 
  • Equipment: Safe means of access is crucial. When rigged, and with a safety net in place, the gangway represented a safe means of access; however, the tidal state meant it was no longer safe to be used. The crew acted to remedy this and rig alternative means of access, but the shore worker was impatient to leave and, tempted by what he perceived to be an easy jump to the jetty, he contravened the crew’s instructions and took an unsafe route off the vessel.

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.