LTI: person suffered serious crush injuries

  • Safety Flash
  • Published on 30 November 2022
  • Generated on 22 February 2025
  • IMCA SF 27/22
  • 2 minute read

During offshore drilling operations, a drilling assistant sustained serious crush injuries, resulting in several weeks away from work.  

What happened?

He was injured when he leaned out of the rooster box, between the guard railings, and was caught between the compensator carriage and the rooster box.

Diagram of position of crew

What went wrong?

  • No-one STOPPED THE JOB: people on the back deck did not challenge unsafe behaviour: people remained in the rooster box in between tool-handling operations.
  • There was inadequate management supervision – no-one verified and monitored compliance with the applicable rules, regulations and good practice.
  • Procedures were not adequately controlled, maintained, and shared.
  • Hazards associated with the tasks were not adequately identified and assessed in the preparation onshore, nor execution offshore.
  • There was a lack of means of communication and observation (such as audio comms and CCTV) to support the management of deck activities.
  • Previous lessons learned during other geotechnical drilling operations were not adequately captured in the drilling manual, shared and/or implemented on this project.

Recommendations and actions taken

  • Our member took the following actions and recommendations
    • Ensured that the procedures and work instructions supporting the operations were controlled, up to date, relevant to the operations and shared, ensuring that the team executing the operations were adequately familiarised.
    • Hazard identification tools  such as HAZOPS, HAZID, Risk assessment, Task risk assessment or SLAM (“Stop, Look, Analyze, Manage”) are critical in ensuring all stakeholders are aware of all the risks and mitigations, reducing the risk to “as low as reasonably practicable”.
    • Adequate communication is essential between employees and supervisors, and where required should be supplemented via electronic means.
    • Safety barriers and devices (e.g. railings) should not be bypassed or defeated.
    • Regularly reinforce messaging to ensure that in the event of any process change or where a hazard is identified, all of us are empowered to speak up and STOP THE JOB without fear of consequence or retaliation.

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.