UK HSE: Two workers suffer multiple burn injuries

  • Safety Flash
  • Published on 15 September 2020
  • Generated on 9 April 2025
  • IMCA SF 27/20
  • 1 minute read

What happened?

An oil refinery company was sentenced for safety breaches after a 2013 incident in which two workers suffered life-changing injuries from an uncontrolled release of high pressure and high temperature steam.

The two workers, one of whom was an apprentice were re-assembling high pressure steam pipework following maintenance of a steam turbine driven pump.

See press release here.

What were the causes? What went wrong?

During the process, they were exposed to an uncontrolled release of high pressure, high temperature steam of around 250°C. The uncontrolled release resulted in the 53-year-old employee receiving burns to his lower back and legs, and the 20-year-old apprentice receiving extremely serious burns to his torso, chest, arms and legs. At the time of the incident, these injures were life threatening.

Investigation found a series of failures with the company’s “safe system of work”. A number of personnel involved in the implementation of the company’s safe isolation procedure of the steam system had failed to complete all the required checks and verifications to reduce the associated risks.

Latest Safety Flashes:

Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more
LTI: rope under tension moved and hit person’s hand

A member of the crew suffered a serious hand injury when struck by a rope under tension.

Read more
Injuries during lifting operations

A member reports two separate lifting activities involving failure of lifting equipment and resulting in minor injuries to nearby personnel.

Read more
Finger injury during manual handling

An IMCA’s members’ utilities supplier in the United States reports a serious finger injury during manual handling

Read more
Acetylene gas explosion

There was a small explosion and fire when crew were working on an oxy-acetylene system.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.