BSEE: Hazards associated with cranes on idle facilities
- Safety Flash
- Published on 10 November 2022
- Generated on 29 April 2025
- IMCA SF 25/22
- 3 minute read
Jump to:
The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert #448 relating to hazards associated with cranes on idle facilities posing safety and environmental risks.

What happened?
BSEE inspectors have observed multiple crane components in poor condition on idle facilities throughout the Gulf of Mexico. Additionally, BSEE inspectors have noted various crane components missing that were previously attached by crane cables.
After extended periods of inactivity, with little or no operator inspection and maintenance, lifting equipment deteriorates due to harsh offshore environmental conditions. BSEE inspectors have observed corrosion on numerous crane cables, which support main blocks, auxiliary balls, overhaul/headache hook balls, and anti-two block equipment. Without proper oversight, the weakened cables have parted, resulting in cables and associated crane components dropping from elevation.
In addition, diminished integrity of wire rope and synthetic slings exposed to weather elements have also been identified as dropped object hazards. These slings are sometimes used to support heavy water hoses and diesel fuel hoses. If the slings fail, there is a potential for severe consequences. The dropped objects can potentially pose a safety risk to personnel boarding the facility or individuals nearby the facility, such as offshore support vessel crewmembers or commercial/recreational fishermen. The dropped objects can also become marine debris, posing environmental risks.
Along with dropped object hazards, potential pollution threats associated with inactive cranes on idle facilities have been identified by BSEE inspectors. Defective fittings, hoses, and leaking diesel/hydraulic reservoirs have been observed across multiple idle platforms.
As most inactive cranes on idle structures have been taken permanently out of service, they no longer require an annual inspection by a qualified inspector. Consequently, in most cases preventative or corrective maintenance has been disregarded.
BSEE recommendations
- Removing all blocks and balls from inactive cranes on idle facilities. If immediate removal is not possible, temporarily secure the blocks/balls with straps or slings that are in adequate condition to prevent dropped objects hazards.
- Conducting a full-function operation inspection when an out of service crane is being put back into service, paying special attention to the lubrication of the wire ropes. All slings on idle facilities that are kept on outboard brackets should be appropriately stored or discarded to eliminate the possibility of falling overboard.
- Clearing diesel and hydraulic reservoirs and associated hoses on cranes that have been permanently taken out of service, to eliminate pollution potential.
Related safety flashes
-
IMCA SF 01/22
10 January 2022
-
IMCA SF 16/21
9 June 2021
-
IMCA SF 31/17
15 December 2017
-
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.