Near Miss – Damaged Rig Hose

  • Safety Flash
  • Published on 31 August 2021
  • Generated on 7 April 2025
  • IMCA SF 24/21
  • 1 minute read

What happened?

A vessel was engaged in routine operations receiving contaminated oil-based mud from a rig. Upon disconnecting the rig hose and vessel side coupling it was discovered that the inner rubber lining of the rig hose had peeled out and got caught at the junction of the connection.

It was determined that should the blockage have prevented the flow of oil-based mud it could have resulted in a significant environmental incident as a result of hose failure due to back pressure.

inner rubber lining of rig hose

inner rubber lining of rig hose

rig hose

rig hose

What was the cause?

Rig side hose inner lining parted from sheath and got caught between connections.

Actions

  • Ensure that hoses are in good condition, properly certified, and in compliance with required standards, before use.

  • Conduct a visual check on hoses before use.

  • Remember that anyone can enact stop work authority if they see something unsafe.

Latest Safety Flashes:

Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more
LTI: rope under tension moved and hit person’s hand

A member of the crew suffered a serious hand injury when struck by a rope under tension.

Read more
Injuries during lifting operations

A member reports two separate lifting activities involving failure of lifting equipment and resulting in minor injuries to nearby personnel.

Read more
Finger injury during manual handling

An IMCA’s members’ utilities supplier in the United States reports a serious finger injury during manual handling

Read more
Acetylene gas explosion

There was a small explosion and fire when crew were working on an oxy-acetylene system.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.