Worker was injured by a forklift truck
- Safety Flash
- Published on 1 September 2017
- Generated on 26 December 2024
- IMCA SF 22/17
- 1 minute read
Jump to:
A worker was struck by a reversing forklift truck which resulted in him fracturing his pelvis. His employer was prosecuted by the UK Health & Safety Executive (UK HSE) and fined.
What went wrong? What were the causes?
Investigation by the UK HSE found that the company had failed to:
- consider the risk created by vehicles and pedestrians operating in the same area
- implement a traffic management plan to ensure workers and vehicles were adequately segregated
- install physical barriers to clearly segregate pedestrians and vehicles.
An HSE inspector said: “This incident could so easily have been avoided by simply carrying out correct control measures and safe working practices.”
Members may wish to review the following incident:
- Fatality: Crew member struck by forklift during quayside operations
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.