Double man overboard resulting in one fatality

  • Safety Flash
  • Published on 13 July 2020
  • Generated on 26 April 2025
  • IMCA SF 21/20
  • 4 minute read

What happened?

During preparations for disconnecting a tow tug which was moored to a barge in turn moored to the jetty, a crew member of the tow tug fell into water between the tow tug and the barge.  A second crew member also fell into the water during attempts to rescue his colleague.

Following a worsening of the weather, it was decided to disconnect the tow tug from the barge.  The Chief Mate stepped over to the barge to check certain equipment, but found that he needed a torch to do so.  He called for a torch by radio.  An AB collected a torch and made his way to deck where the 2nd Mate was acting as safety watch for the Chief Mate.  The AB handed over his radio to the 2nd Mate, who did not have a radio.  Whilst the 2nd Mate was occupied with the radio, he took his eye off the AB who, at this point, fell into the water.  When the 2nd Mate realised what had happened he shouted “Man Over Board” and attempted to rescue the AB.  During his attempts he also fell into the water.  In the meantime the MOB alarm was raised and all hands were on deck.  The 2nd Mate was helped out of the water.  The AB was still in the water and had now lost consciousness.  After a number of attempts he was pulled towards the rescue zone door by a boat hook, where he was manually lifted out of the water. The 2nd Mate was treated for hypothermia. The AB was administered CPR and AED by the crew until medical assistance arrived.  The AB was medevaced by helicopter but did not survive.

What went wrong?

  • Vessel to vessel transfer was accepted and regarded as a routine activity.
  • Risk awareness did not deal with specific risks of routine activities in non-routine circumstances. The focus is on what has to be done, not on how/risks involved.
  • MOB between two stationary vessels was not specifically addressed in procedures, risk assessments or drills related to MOB. Rescue equipment was not primarily suitable for rescuing MOB from between two vessels.
During preparations for disconnecting a tow tug which was moored to a barge in turn moored to the jetty, a crew member of the tow tug fell into water between the tow tug and the barge

What were the causes?

Our member notes that both the AB and the 2nd Mate were wearing inflatable lifejackets which slipped up their heads whilst they were in the water.

Procedures and risk assessments:

  • Procedures allowed direct transfer from vessel to vessel in adverse weather conditions, exceeding defined conditions (captain’s discretion).
  • There was no requirement for “last minute risk assessment” (LMRA) before starting routine activities under suboptimal circumstances.
  • Toolbox talks were primarily focused on which activities, less on how to execute and risks involved.
  • Risk of hypothermia was not specified in the client’s procedures/risk assessments.

Man overboard!

  • MOB drills and processes tend to be related to open sea situations, and do not address falling in between two (stationary) vessels.
  • Inflatable jackets are not part of drills.
  • Rescue equipment was not suitable for swift retrieval of MOB between stationary vessels.
  • The wearing of thermal suits was not mandatory.
  • Inflatable life jackets with crotch straps was not mandatory.
A second crew member also fell into the water during attempts to rescue his colleague

Actions

Procedures, risk assessment and toolbox talks:

  • Review procedures with regard to direct vessel to vessel personnel transfer.
  • Include the risk of hypothermia in procedures and risk assessments related to falling in the water.
  • Review MOB procedures and drills to include MOB situations between two stationary vessels/between vessel and quayside.
  • Ensure that toolbox talks not only deal with what has to be done, but also with how it should be done and the specific situational risks involved, including changes in operating conditions. Ensure that when work cannot be carried out safely anymore, the Stop Work authority is applied.
  • Properly assess additional risks of carrying out routine activities under non-routine conditions.

 Equipment

  • Ensure that heaving line and bag are applied for transfer of equipment/tools (such as a torch in this case) from vessel to vessel.
  • Ensure that the required equipment/tools are defined prior to carrying out a non-routine job.
  • Review MOB equipment and techniques used for rescue in limited situations, for example between two stationary vessels or between vessel and quayside.
  • Consider introducing life jackets with crotch straps.

Members may wish to refer to

  • HSS025 Guidance on the Transfer of Personnel to and from Offshore Vessels and Structures
  • HSS029 Mooring practice safety guidance for offshore vessels when alongside in ports and harbours
  • HSS036 In the line of fire video
  • HSS038 Mooring incidents video

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.