MSF – Two recent dropped object incidents

  • Safety Flash
  • Published on 15 August 2023
  • Generated on 22 February 2025
  • IMCA SF 20/23
  • 3 minute read

The Marine Safety Forum (MSF) has published safety alerts on two recent dropped object incidents, both of which have learning value for IMCA Members.

Incident 1: What happened?

A breakaway coupling became a dropped object.

It fell unnoticed to deck on a semi-submersible accommodation vessel.

Later investigation identified where the breakaway coupling had fallen from. 

Another coupling was found with early signs of failure, with one of the breakaway studs found loose and able to be moved around freely.

What went wrong?

The MSF notes that planned maintenance of the couplings was not aligned with OEM guidelines – it was found that the breakaway studs had been in place for longer than OEM recommendations.

Also, the vessel was in lay-up and there was no reason for the couplings to be in place during layup.

The couplings should have been removed at end of contract to remove any risk of a dropped object.

A breakaway coupling became a dropped object. It fell unnoticed to deck on a semisubmersible accommodation vessel. Later investigation identified where the breakaway coupling had fallen from.  Another coupling was found with early signs of failure, with one of the breakaway studs found loose and able to be  moved around freely.

Actions

Actions

  • Amend planned maintenance system to reflect OEM requirements and recommendations.

  • Amend procedures to ensure hoses and couplings are not left in situ at height, when this is not required.

  • Review potential use of drop net / secondary restraint.

See Breakaway Coupling becomes a Dropped Object for further details.

Incident 2: What happened?

A barrier tape mechanism handle weighing 278 g fell 45 m from an offshore platform onto the deck of a supply vessel.

During routine supply vessel operations, a deck crew person on an offshore platform was establishing barriers for safe lifting of cargo onto the platform’s weather deck.

On extraction of the fixed barrier tape, the handle was seen to eject from the mechanism and fall, eventually landing 45 m below on the deck of a supply vessel.

Whilst nobody on the supply vessel was on deck at the time, this had the potential to have been a fatality.

What went wrong?

This type of barrier tape was only used by the offshore platform deck crew and was all fixed to the outboard handrails near laydown areas.

The handle was fastened with a grub screw to a round shaft with no keyway or secondary retaining mechanism.

The design is such that as the tape spools out the handle spins; this provided the lateral force to allow the handle to eject out over the handrail and down onto the supply vessel deck.

A review of other new and older mechanisms onboard found similar loose moving handles but none that would readily fall out.

 During routine supply vessel operations, a deck crew person on an offshore platform was establishing  barriers for safe lifting of cargo onto the platform’s weather deck. On extraction of the fixed barrier tape the handle  was seen to eject from the mechanism and fall, eventually landing 45m below onto the deck of a supply vessel.  Whilst nobody on the supply vessel was on the deck at the time, this had the potential to have been a fatality.

Actions

  • Check if similar barrier tape mechanisms are used and check integrity of handle fixtures.

  • Consider relocation away from handrails to remove the potential for rotating mechanisms to fail and fall to levels below, the sea or supply vessels.

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.