LTI: Crush injury to middle and index finger

  • Safety Flash
  • Published on 2 August 2017
  • Generated on 8 May 2025
  • IMCA SF 19/17
  • 2 minute read

Riggers on a vessel were moving heavy deck plates (2.45 m x 1.2 m x 5 mm, weighing 114 kg) when one of them got his hand caught, causing a crush injury. 

What happened?

The riggers were tasked with cleaning an area on the vessel. To do this, they had to lift the deck plates, degrease the deck below and power wash from the suspended deck above. During the task, it was noted that the debris and corrosion on the deck below would require shot blasting. A management decision was made to remove all the deck plates and stack them against handrails in preparation for this work.

While moving one of the plates and turning it through 90° onto its long axis, to be slid over the angle beam foundation, the leading corner of the plate caught on a section of angle beam and stopped sliding. A rigger (the IP in the sketch below) attempted to rectify this by lifting the corner, enabling the rest of the team to push the deck plate. Upon setting down the deck plate, his middle and index finger became trapped between the angle beam foundation and the deck plate, causing a serious injury.

Image3 (1)

What went wrong? What were the causes?

  • The incident occurred as a result of ‘scope creep’. There was no proper Management of Change.

  • The size and weight of the deck plates did not allow for a safe and ergonomically friendly means of moving them, especially over the angle beam foundation.

  • The injured person placed his hand beneath the deck plate despite being instructed not to do so by his supervisor.

  • The injured person was wearing welding gloves, rather than the impact gloves required in the JRA (job risk analysis).

  • Pinch points had been discussed in a task-specific toolbox talk held just before starting the job.

What lessons were learned? What actions were taken?

  • The change of job scope (‘scope creep’) should have triggered a stop, leading to the change being properly managed. A new permit should have been raised with a task specific JRA.

  • Members may wish to use this example to highlight the issue of ‘scope creep’ and appropriate Management of Change – particularly where manual handling is involved.

See IMCA HSS001Guidelines for management of change

Latest Safety Flashes:

BSEE: Nitrogen Cylinder Rupture Causing Worker Injuries and Equipment Damage

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 494 relating to a Nitrogen Cylinder rupture which caused injuries and equipment damage.

Read more
Person fractured foot during elevator inspection
Read more
Detergent chemical burn

Leaked detergent resulted in slight chemical burns onboard a vessel.

Read more
Positive findings and good practices

A member highlights some examples of positive findings and good practices on board some of their vessels.

Read more
Hydrogen Sulphide (H2S) detected onboard vessel

Several persons reported to bridge about a smell of septic or rotten eggs that was present all over the vessel. Hydrogen Sulphide (H2S) was suspected.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.