Hand injury whilst using pillar drill
- Safety Flash
- Published on 2 August 2017
- Generated on 24 April 2025
- IMCA SF 19/17
- 2 minute read
Jump to:
What happened?
The Marine Safety Forum (MSF) has published an alert in which someone was injured whilst using a pillar drill. An experienced engineer was changing out a drill bit on a tower drill in the engine room workshop. While doing so he inadvertently operated the wrong handle and started the drill. The engineer was wearing gloves to carry out this task and as the drill turned the glove caught and turned with the drill bit, trapping his hand inside and causing a hand injury.
He was sent ashore for treatment.
What went wrong/causes
The subsequent investigation highlighted several safety critical points, a selection of which are noted below:
- The drill had multi-function controls (including clutch speed, gears, slow and fast operation, on/off switches) none of which were actually marked to indicate their purpose.
- By its design, the emergency stop button for the drill did not clearly identify to the operator when it was engaged or deactivated.
- There was no ‘green light’ (or similar indicator) to show when the equipment was ‘energised’.
Any modification of equipment should only be done after consultation and agreement with the manufacturer to ensure the modification does not adversely interfere or affect any of the other functions of the drill.
Lessons learnt/actions taken
- The company reporting the incident introduced ‘drill familiarisation’ to the engineers’ induction.
- A full and comprehensive risk assessment should be carried out for the use of all engine room equipment.
- Engineers intending to use the equipment should be fully familiar with those risk assessments and comply with their requirements.
- IMCA notes that in many countries there are regulatory requirements (the Provision and Use of Work Equipment Regulations (PUWER) in the UK) which should have been applied with regard to equipment control markings.
Note: A more recent model of the same drill incorporates a safety feature where the drill cannot be operated if the drill guard is in the open position. Such safety features should be function-checked to ensure they are fully operational before carrying out any drill changes.
Related Safety Flashes
-
IMCA SF 04/15
20 March 2015
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.