Parted tag line caused damage during lifting operations

  • Safety Flash
  • Published on 29 August 2024
  • Generated on 25 April 2025
  • IMCA SF 17/24
  • 2 minute read

A tagline parted under excess tension when moving a LiDAR buoy weighing 2.4 tonnes, causing the buoy to move in an unexpected way.

What happened?

A tagline parted under excess tension when moving a LiDAR buoy weighing 2.4 tonnes, causing the buoy to move in an unexpected way. The incident occurred when the buoy controlled by two tag lines was being recovered to deck using the vessel crane. A worker on deck, who had been positioned to support the landing of the buoy onto its landing cradle, was struck when the buoy moved. Additionally, the uncontrolled movement of the buoy caused damage to the vessel and the buoy itself. The worker was not harmed.

What went wrong?

Our members’ investigation established that:

  • The worker who was struck was in the wrong place at the wrong time – they were improperly positioned on deck.
  • There was no documented process detailing the recovery of buoys.
  • The lift plan was not compliant with existing company procedures.
  • The Tool Box Talk (TBT) lacked detail and was too generic.
  • There was insufficient supervision and training in place, as the person in charge of the lift was not trained as a lift supervisor, and was busy working a tag line at the time of the event.

Lessons

  • Ensure lift activities are properly planned and approved using a lift plan which identifies all the risks and helps to communicate the task at the worksite during the Toolbox talk.
  • Lift supervisors should supervise effectively and monitor a lifting operation without distraction. Don’t get involved with actually doing the job yourself – take a step back and keep an overview of the situation.
  • Stop the job if a Life Saving Rule is not being followed – Stop, reposition and start again when it is safe to do so.
  • Dynamic risk assessments are crucial. All the time, be asking yourself questions such as:
    • Where are you in relation to the load?
    • Where is the load going?
    • Where is your exit route?

Actions taken

  • Lift Plans for this task were updated and approved by a qualified person.
  • Relevant crew completed lift supervisor training to comply with company and local regulatory requirements.
  • Re-iterated the importance and usage of standard lift plans.
  • Re-assessed training plans to ensure sufficiently trained crew are available for future lifting operations.

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.