Uncontrolled movement of crane jib during inspection

  • Safety Flash
  • Published on 3 December 2008
  • Generated on 29 April 2025
  • IMCA SF 17/08
  • 2 minute read

A Member has reported an incidence of uncontrolled movement of a crane jib during inspection operations. 

What happened?

The crane boom/knuckle had been lowered to deck to enable access to the main hoist sheave for inspection and maintenance purposes. The crane was powered down and the operator was not in the cab. During the inspection there was an uncontrolled movement of the knuckle section along the deck of approximately 30cm towards the crane pedestal.

The hydraulic cylinders in the main boom were not fully closed when the crane was stowed in this position; therefore the weight of the jib was able to overcome the friction on deck and thus caused the movement of the knuckle head across the deck. At the time of the movement the inspector had been positioned close to the equipment in order to gain access on either side for a complete overview.

Main boom cylinders not fully closed

Main boom cylinders not fully closed

Main boom cylinders fully closed

Main boom cylinders fully closed

A number of key lessons were drawn from this near-miss:

  • Conduct such inspections and ‘routine’ maintenance with the crane stowed in dedicated parking position i.e. crane crutch.
  • Ensure that the main boom cylinders are fully closed to avoid uncontrolled movement of crane jib.
  • Follow approved procedures and always fully brief third party personnel during a toolbox talk prior to commencing the operation.
  • Follow and adhere to the permit to work system, review and risk-assess specific tasks.
  • Ensure that a complete and thorough shift handover is conducted at all times and strive to identify any hazards while the job is in progress; . Barrier off work-site and ensure all personnel are aware of the potential hazards.
Deck area where uncontrolled movement of the knuckle occurred

Deck area where uncontrolled movement of the knuckle occurred

Correct angles and position of crane

Correct angles and position of crane

Correct boom position during the inspection operation

Correct boom position during the inspection operation Safety Event Published: 3 December 2008 Download: IMCA SF 17/08 IMCA Safety Flashes 2024 2023 2022 2021 2020 2019 2018 2017 2016 More ...

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.