MSF: Serious hand injury – high pressure air

  • Safety Flash
  • Published on 14 August 2024
  • Generated on 22 February 2025
  • IMCA SF 16/24
  • 3 minute read

The Marine Safety Forum (MSF) has published Safety Alert 24-05 relating to a finger injury caused by a release of high pressure air.

Hand and finger injuries

Members continue to report hand and finger injuries. In last year’s safety statistics, 42% of LTIs reported by IMCA members involved injuries caused when workers got into the Line of Fire. What do we need to do to stop workers putting their hands and fingers in dangerous places? We all want to get the job done – but that one quick pause, whilst we stop to think, could make ALL the difference. Think:

  • Is there a better way to do this?
  • Could I use a tool instead?
  • Should there be a guard? Should I have gloves on?
  • Is this still too hot to touch? Is it live or is it still spinning?  
  • Think carefully before putting your hands where you can’t see them.

What happened?

The Marine Safety Forum (MSF) has published Safety Alert 24-05 relating to a finger injury caused by a release of high pressure air. The incident occurred during a vessel fire drill; the fire team were being assisted with putting on Breathing Apparatus (BA) sets. The assisting crewmember inadvertently opened the BA set valve resulting in a release of high pressure air. As a result, the crew members’ finger was impregnated by the high pressure air. The finger that was impregnated showed immediate signs of swelling and the medical support teams advised medevac by helicopter. The injured crew member required surgical treatment, to confirm the extent of the injury and ensure there was no debris injected, and to reduce the risk of infection and tissue damage.

Photo diagram of close-up of valve assembly on BA set

Close-up of valve assembly on BA set

What was the cause?

Investigation found that there was a momentary high-pressure air release from the Pilot Vent Hole – a safety feature in 300 bar rated cylinder valves. The injured crewmember must have inadvertently placed his finger over the Pilot Vent Hole at the moment there was a momentary release of pressure.  

Recommendations (MSF)

  • When replacing a BA bottle on a BA set always ensure that the Cylinder Valve Handwheel connection is tightened as per manufacturer’s instructions.
  • After changing the BA bottle, pressurize the system and listen for any leaks. Test for bubbles caused by leaks using soapy water at the connection points. Tighten connections, if necessary, but close the main valve first.
  • Ensure the pressure gauge reflects the correct pressure.
  • Conduct a breathing check by inhaling through the mask to ensure air is flowing correctly.
  • Verify the low-pressure alarm is functioning properly by momentarily turning off the air supply. When conducting planned maintenance checks the above should also be adhered to and checked.
  • When putting on BA, manufacturer’s instructions should be followed, and if any leaks are observed the main cylinder valve must be closed prior to tightening.  

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.