MSF: Tank corrosion
- Safety Flash
- Published on 9 June 2021
- Generated on 27 April 2025
- IMCA SF 16/21
- 2 minute read
Jump to:
The Marine Safety Forum (MSF) has published Safety Alert 21-07 relating to the discovery of a leak in a tank caused by corrosion
What happened?
During daily tank sounding routines in the engine room on a vessel, there was an unexpected rise in liquid level in the tank. A close check was made which confirmed this finding, and it was decided to open the tank for investigation.
A pinhole leak was discovered in the structure beneath the sounding pipe. This allowed salt water to enter the space from outside the tank. The vessel was sent for repairs.
What was the cause?
Initial investigation by the ship’s engineers concluded that the striking plate at the bottom of the sounding pipe was missing. This allowed the brass weight to repeatedly strike the steelwork, damaging the paint coating and exposing the steelwork to corrosion.
Further investigation revealed that:
- The tank had been inspected and maintained in accordance with company procedure.
- The brass weight of the sounding tape had damaged the paint coating on the striking plate and steelwork below.
- A corrosive chemical had been incorrectly disposed of and introduced to the tank, accelerating the corrosion process.
- The acid may have become trapped under bubbles of damaged paint, allowing concentrated corrosion over the short time.
- The combination of exposed steelwork and caustic solution destroyed the striking plate and steelwork below.
Actions
- Effective repairs were carried out onboard in collaboration with third party welders and divers.
- All crew were reminded of the importance of correct chemical handling – including safe disposal. On board a vessel, there are many different chemicals used; some of these chemicals pose a serious health risk with some being extremely caustic. These chemicals should be used in the appropriate and prescribed way and not misused.
- Safety Data Sheets (SDS) are provided for safety and information and contain all relevant information about the chemical, such as the physical and chemical properties, hazard identification, handling and storage and disposal considerations.
- Caustic or otherwise dangerous chemicals, and their containers, should be disposed of to an authorised hazardous or special waste collection point in accordance with any local regulation.
Members may wish to refer to:
- IMCA pocket safety card Hazardous substances safety guide.
Related Safety Flashes
-
IMCA SF 23/17
21 September 2017
-
-
IMCA SF 16/17
27 June 2017
-
-
IMCA SF 01/02
1 January 2002
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.