Man overboard fatality

  • Safety Flash
  • Published on 5 July 2019
  • Generated on 21 June 2026
  • IMCA SF 16/19
  • 3 minute read

The US Coast Guard (USCG) has published Safety Alert 05-19 relating to a man overboard fatality. 

What happened?

The incident occurred when a very large (330m) container ship arrived in port in heavy weather (40 knot winds and 4m swell.)

The vessel was on a WNW course with seas on the vessel’s starboard quarter, manoeuvring at about 10 knots to make a lee in preparation to embark a ship’s pilot at a port side hatch.

Two crewmen were preparing for the pilot’s arrival, behind the hydraulically operated bi-fold hatch door.  This was located forward of the bridge and approximately 4 m above the waterline – see photographs.

As the vessel manoeuvered, it was hit by heavy seas that forced the hatch door open, resulting in flooding of the embarkation space, sweeping one crewman out to sea and injuring another.

The incident occurred when a very large (330m) container ship arrived in port in heavy weather (40 knot winds and 4m swell.)

The crewman who was washed overboard and subsequently swept out to sea was lost and presumed dead after 28 hours of searching by the local Coast Guard.

The injured crewman suffered a broken leg when the pilot ladder fell on him.  The hatch door itself was damaged.

As the vessel manoeuvered, it was hit by heavy seas that forced the hatch door open, resulting in flooding of the embarkation space, sweeping one crewman out to sea and injuring another

What went wrong? What was the cause?

  • The two crewmen were unable to see the sea from their position behind the hatch door. As they opened the door, seas unexpectedly struck and violently forced it open, flooding the space.

  • One of them was not wearing a harness or safety line, nor a personal flotation device and was washed overboard and subsequently swept out to sea.

The USCG reiterates the need to take the greatest care with personnel transfer at sea, especially in heavy weather conditions.

Even though the side hatch door was located on the port side and was being brought onto the vessel’s lee, the crew’s inability to observe and assess the sea conditions combined with the ship’s roll and sea state presented significant risks.

The USCG reiterates the need to take the greatest care with personnel transfer at sea, especially in heavy weather conditions. Even though the side hatch door was located on the port side and was being brought onto the vessel’s lee, the crew’s inability to observe and assess the sea conditions combined with the ship’s roll and sea state presented significant risks.

The US Coast Guard strongly recommends the following actions:

  • A thorough review and update of vessel Safety Management Systems (SMS), procedural manuals and guidance that relates to pilot transfers.

  • Reinforce the importance of wearing personal protection devices and safety lines when working over the side of a vessel, when exposed to the elements or when there is an absence of barrier that could prevent an accidental water entry.

  • Ensure officers and crew identify potential hazards and conduct a risk assessment, to include a consideration of weather conditions, prior to opening hatch doors of this sort.

  • Ensure crew communications between navigation watch officers and crew, in situations such as this, are clear and provide suitable supervision of activities, considering sea state and other changing conditions.
    Members may wish to search the Safety Flash Archive for terms such as pilot or man overboard.

Latest Safety Flashes:

Arm injury – need for focus on safe isolation and task control

A worker sustained an arm injury while troubleshooting a malfunctioning garbage compactor.

Read more
Floodlamp causes scaffold board to start smouldering

Workers on the accommodation deck noticed light smoke emanating from a nearby scaffold structure.

Read more
Lamp fixture fire in office cabin

A fire broke out in a ceiling lamp fitting in a cabin on a vessel.

Read more
BSEE: Prevent fires by inspecting cords, plugs and welding leads before use

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 515.

Read more
More positive stories

Some more stories of good things happening – what went right.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.