Near-miss: ROV fuse bolt failure
- Safety Flash
- Published on 10 November 2009
- Generated on 22 February 2025
- IMCA SF 16/09
- 2 minute read
Jump to:
A Member has reported an incident in which a crew member was narrowly missed by the head of a fuse bolt which had been shot out of a remotely operated vehicle (ROV) manipulator arm at high speed.
What happened?
It occurred as normal pre-dive checks were being completed on the ROV. The manipulator arm being tested was cycled and, during the test, the fuse bolt securing the jaws of the manipulator failed. This caused the head of the bolt to shoot out of the manipulator arm at high speed. The head of the bolt passed close to an ROV technician who could have been severely injured had it hit him. There were no injuries.
The manufacturer’s operating procedures recommend that personnel stay clear of the operational envelope of the manipulator during functional testing on deck. However, owing to the high levels of kinetic energy shown in this failure, additional caution should be exercised, for example, standing further back, cordoning off the area and ensuring that non-essential personnel are clear.
What were the causes?
Further investigation revealed that:
- The fuse bolt had failed under water during the previous dive.
- The manipulator had been exposed to heavy work during the previous dive and this had led to other components in the arm and wrist assembly being damaged sufficiently to lead to this second fuse bolt failure on deck.
Actions
The following actions were taken:
- The ejected fuse bolt was recovered and the manipulator and ROV made ready for dive.
- Additional controls were identified which would prevent a recurrence of this type of incident.
- CCTV footage of the failure was prepared as a safety presentation.
- The manufacturer of the manipulator arm (Schilling Robotics) was informed.
- The manufacturer developed and published a safety bulletin (attached).
- The fuse bolt was subjected to failure analysis to better understand why it failed so dramatically.
The following further actions are recommended:
- Manual operation of manipulator jaws to be conducted prior to energising hydraulics.
- ROV personnel should ensure when completing deck checks on ROV manipulators that the arm is pointing away (or even outboard) from personnel and assets in the immediate area.
- Access to the area immediately around ROV should be controlled during pre-dive deck checks.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.