Vessel gangway rolled off platform tower and fell to the quayside in high wind

  • Safety Flash
  • Published on 28 April 2020
  • Generated on 27 April 2025
  • IMCA SF 14/20
  • 2 minute read

What happened?

During stormy weather, there were sudden and violent gusts of wind of greater than 50 knots, resulting in a vessel alongside being pushed off the quay. This resulted in the gangway rolling off the platform tower and falling approximately 5.2 m to the quay.

The vessel’s side of the gangway remained attached to the vessel.

There was no-one nearby at the time; no-one was harmed; however, the incident had the potential to cause fatal injury.

The incident occurred when a vessel was in port for maintenance.

A shipyard’s gangway was attached to the vessel’s deck and placed on top of a stairway tower platform on the quayside. 

The gangway was only fixed at the vessel side and could move via rollers on the platform side.

The platform was used to assist with tidal height variation.

Investigation noted the following:

  • The potential risk of a falling gangway was not considered or recognised. There was no previous history of issues or incidents with this setup, the task was considered as a low risk routine duty by the shipyard (IMCA bold).
  • During sudden, violent gusts of wind, the mooring ropes stretched allowing the vessel to move away from Yokohama fenders and quay. Mooring ropes worked as designed.
  • In response to the available weather forecast, precautions where put in place, including additional mooring lines, additional manpower to monitor mooring lines and gangway watchman closely observing gangway movements.
  • The was no consideration for safety in design. The positioning of the stairs in front of the platform forced personnel to pass underneath the gangway which can be classified as supported load.
  • The incident had the potential to cause a fatal injury.
Vessel moves away from the quay, pushed by sudden and violent gust of wind

vessel moves away from the quay, pushed by sudden and violent gust of wind

Gangway moves with the vessel and falls off the platform tower

gangway moves with the vessel and falls off the platform tower

What actions were taken?

  • Damaged gangway was removed, and alternative gangway fitted to a lower deck direct to the quayside.

  • Ensure weather reports are reviewed with regard to operations that involve equipment which does not belong to vessel.

  • Could this happen on your vessel? Ensure that risk assessments suitably address concerns related to safe access and egress to your vessel.

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.