Safe Use of Ladders and Stepladders

  • Safety Flash
  • Published on 12 May 2022
  • Generated on 25 June 2026
  • IMCA SF 12/22
  • 2 minute read

The Ladder Association, in co-operation with the UK Health and Safety Executive (HSE) has published Guidance Document LA455 on the safe use of ladders and stepladders.

The Ladder Association Guidance Document LA455 can be found here: LA455 - The Ladder Association

In the UK, falls when working at height remain a common kind of workplace fatality, accounting for around a quarter of all worker deaths and 8% of all non-fatal injuries every year, with many involving a fall off a ladder. It’s essential that people use the right type of ladder for a task and know how to use it safely. The guidance is for employers on the simple, sensible precautions they should take to keep people safe when using portable leaning ladders and stepladders in the workplace. It will also be useful for employees and their representatives.

Safe Use of Ladders poster
Safe Use of Ladders

It covers such areas as:

  • When is a ladder the most suitable equipment? “As a guide, if your task would require staying up a leaning ladder or stepladder for more than 30 minutes at a time, it is recommended you use alternative equipment. You should only use ladders in situations where they can be used safely, e.g. where the ladder will be level and stable, and can be secured (where it is reasonably practicable to do so).”
  • Who should use a ladder at work?
  • Checking your ladder before you use it – make use of pre-use checklists.
  • Using your ladder safely – simple precautions can minimise the risk of a fall.
  • What about the place of work where the ladder will be used – guidance on where a ladder should and should not be used.
  • What are the options for securing ladders?
  • What about ladders used for access?
  • What about the condition of the equipment – ensuring “that any ladder or stepladder is both suitable for the work task and in a safe condition before use. As a guide, only use ladders or stepladders that:
    • have no visible defects. They should have a pre-use check each working day.
    • have an up-to-date record of the detailed visual inspections carried out regularly by a competent person. These should be done in accordance with the manufacturer’s instructions. 
    • are suitable for the intended use, i.e. are strong and robust enough for the job.
    • have been maintained and stored in accordance with the manufacturer’s instructions.”

Latest Safety Flashes:

Arm injury – need for focus on safe isolation and task control

A worker sustained an arm injury while troubleshooting a malfunctioning garbage compactor.

Read more
Floodlamp causes scaffold board to start smouldering

Workers on the accommodation deck noticed light smoke emanating from a nearby scaffold structure.

Read more
Lamp fixture fire in office cabin

A fire broke out in a ceiling lamp fitting in a cabin on a vessel.

Read more
BSEE: Prevent fires by inspecting cords, plugs and welding leads before use

The United States Bureau of Safety and Environmental Enforcement (BSEE) has published Safety Alert 515.

Read more
More positive stories

Some more stories of good things happening – what went right.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.