Recent prosecutions by the UK HSE

  • Safety Flash
  • Published on 14 June 2018
  • Generated on 22 February 2025
  • IMCA SF 12/18
  • 2 minute read

The UK Health & Safety Executive (UK HSE) publishes regular press releases relating to safety incidents. These can be found on the HSE website.

IMCA monitors these publications and passes on brief information relating to some of these incidents, from which members may draw lessons.

Incident 1 – Worker crushed while unloading a vehicle

A worker suffered crush injuries while unloading a vehicle from a visiting delivery lorry. He was unchaining a vehicle ramp from a delivery lorry when the lorry moved forward with one chain still attached to the ramp, crushing the worker between the ramp and a barrier.

Investigation by the UK HSE found that there was:

  • A failure to fully control the risks arising from the operation of vehicle loading and unloading ramps.

  • There were no suitably robust systems of work implemented.

  • There was insufficient training to allow workers to safely unload vehicles.

  • There was no briefing for visiting drivers to the worksite.

The HSE inspector noted that something as simple as removing the visiting lorry driver’s keys until the procedure was safely completed was one method which could have prevented such an occurrence.

Incident 2 – Workers suffer serious burns in electrical flashover

Two workers suffered serious burns from an electrical flashover. They were working to reinstate the power supply to a furnace after repair work had been completed by contractors. After replacing the fuses, they shut the door to the fuse panel which engaged the interlock and tried to close the main switch. As this would not operate, they opened the panel door and decided to bypass the interlock using a screwdriver in order to try the main switch again. At this point an electrical flashover occurred. Both employees suffered serious skin burns requiring surgery followed by a two week stay in hospital to recover.

An investigation carried out by the UK HSE found that:

  • There were no electrical safety rules, safe systems of work or a permit system in place.

  • There were no recorded systems or rules for working with electricity.

  • There was no assessment of risk and the injured employees were not provided with any specific instructions on how to undertake the work safely.

  • The company also allowed employees to work on live conductors without consideration of the conditions which are stipulated in [UK] law.

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.