Lifeboat damaged whilst being lowered on davit

  • Safety Flash
  • Published on 14 November 2012
  • Generated on 24 April 2025
  • IMCA SF 12/12
  • 2 minute read

A Member has reported an incident in which a lifeboat was damaged. 

What happened?

The incident occurred when the davit was boomed out to lower the lifeboat. The lowering was part of a functionality test after adjustment of limit switches by the manufacturer’s service engineers.

Whilst booming out, one of the remote control wires for lifting the brake got trapped behind a wire sheave arrangement. When the wire became taut, the remote control wire lifted the static brake and the lifeboat started lowering while it was still above the deck. The lifeboat got stuck on its protection fender, from which the stainless steel turnbuckle parted. The lifeboat then swung out sharply and was damaged in several locations when it swung back in, hitting the side of the vessel. The lifeboat then descended to the water on the centrifugal brake control. It was not possible to stop the process as the remote control wire remained stuck and taut, lifting the static brake.

The lifeboat was moderately damaged, suffering a puncture hole in the starboard side bottom (approx. 5 x 5 cm), crushing damage to the fibre-glass on the starboard forward top (approx. 80 x 15 cm), and loss of some of the water sprinkler tubing, which came off when the lifeboat hit the side of the vessel. No one was in the lifeboat at the time and there were no injuries.

Damage to lifeboat

Damage to lifeboat

Damage to lifeboat

Damage to lifeboat

How remote wire got stuck behind a wire sheave arrangement

How remote wire got stuck behind a wire sheave arrangement

How remote wire got stuck behind a wire sheave arrangement

How remote wire got stuck behind a wire sheave arrangement

During our Member’s investigation the following points were noted:

  • It was unclear when the remote control wire had slipped in between the sheave and sheave guard. It was difficult to observe the many obstacles which could potentially foul this wire.
  • If the remote wire had been kept under adequate tension this would have prevented the likelihood of it fouling.
  • The fact that the lifeboat could be lowered while not yet fully boomed out could be considered a design error. The manufacturers have been asked to investigate this further.
  • The likelihood that the remote wire could become fouled was not foreseen by the manufacturers, and there were no written procedures or instructions covering this.

The following recommendations were made:

  • Persons involved with lifeboat lowering and recovery should ensure that the remote wires are constantly out of the sheave and not fouled with any other rigging.

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.