Near miss: Floor Plate fell from Main Mast during storm
- Safety Flash
- Published on 4 May 2022
- Generated on 24 November 2026
- IMCA SF 11/22
- 2 minute read
Jump to:
A floor plate fell from the main mast to the deck during a storm.
What happened?
At the time there were violent storm force winds of 55 to 60 knots with an 11m swell. A crew member suddenly heard an object falling from above. It landed near the upper deck port forward crane. It was a piece of 50 x 80 cm aluminium plate with 4 holes for securing, weighing about 2Kg. There were no injuries nor property damage.
What went wrong?
The four screws securing the floor plate had sheared. The plate was from the mid platform of the mast at the base the Inmarsat dome mast.
The screws had been replaced by a sub-contractor during fabric repairs, just over one year previously, and were found to be too short, and of too poor a quality, to ensure the plate remained secured adequately.
Actions
- Re-secured the plate with proper fixings.
- Held a thorough check of all similar plates on deck, especially in areas where this particular sub-contractor had been working, so as to avoid similar potential problem.
- Fed back to the sub-contractor about this near miss, requiring higher attention to quality performance in future work.
Related Safety Flashes
-
IMCA SF 18/20
12 June 2020
-
-
IMCA SF 04/18
20 February 2018
-
-
IMCA SF 04/18
20 February 2018
-
-
IMCA SF 20/18
10 September 2018
-
-
IMCA SF 24/17
5 October 2017
-
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.