Life raft dropped to the jetty

  • Safety Flash
  • Published on 16 April 2021
  • Generated on 28 November 2026
  • IMCA SF 11/21
  • 2 minute read

A life raft was inadvertently dropped onto the jetty during replacement of the ratchet straps on the hydrostatic pressure release unit.

What happened?

Three crew members were replacing the securing straps on the life-raft, which were arranged on a common sliding cradle, three rafts on each side of the vessel. 

The strap holding each raft was connected to a hydrostatic release unit at one end, and to a strong point at the other. A ratchet was used to tighten the strap.

The life rafts were individually secured by a crane while the straps were being replaced.

When the crane was holding the topmost life raft, one crew member accidentally released the ratchet strap of the middle raft.

The raft slid off the cradle and dropped approximately 10 metres to the pier. The life-raft container was damaged; no-one was injured.

IMCA SF Life raft dropped to the jetty

What went wrong?

  • Human error lead to accidental release of unsecured raft.

  • There were no watchmen, nor barriers cordoning off the potential drop zone.

What were the causes?

  • The risk assessment was not suitable or sufficient: the risk assessment used for this job was primarily intended for the tasks of lifting the life rafts out of storage.

    • It did not identify the risk of confusing the straps; this particular risk was not discussed during toolbox talks beforehand.

  • The straps were not identified nor temporarily marked before the task – the crewman took the wrong strap.

  • The responsibility of releasing the strap was not clearly assigned to any one particular person, and who was going to do it, was not agreed beforehand.

Actions

  • Develop better situational awareness: the person who released the wrong life raft believed his action was correct.

  • Mistakes will be made: the risks of human error occurring should always be taken into account.

  • Assign clear responsibility: ensure that team members know which task is done by which person – before starting work.

  • Check the drop zones: investigation revealed that the area on the quay underneath the life rafts was not easily accessible because access to the gangway was restricted to comply with ISPS requirements. 

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.