Internal explosion within 12V forklift battery

  • Safety Flash
  • Published on 1 September 2003
  • Generated on 15 February 2026
  • IMCA SF 11/03
  • 2 minute read

A forklift battery was found to be flat and it was changed out with a replacement that was held onboard and tested per procedures, the forklift was also function tested and all were working satisfactorily.

What happened?

The following morning the pre-start up checks on the forklift were carried out, and no problems were identified. The forklift operator than attempted to start the engine. As he did this he heard a loud noise from behind him, he immediately switched off the engine, and turned to see vapour and electrolyte spilling from the battery compartment. The spill was contained, and the electrician was called to make the area safe by disconnecting the battery. The battery was found to have a ruptured cell and was returned to the supplier to determine the cause of the failure. The battery was a 12 volt, sealed, lead acid type.

On inspection it was found that the cell plates within the battery had sulphated and dried, the mud space was also found to be full, which is a natural process with age and this combination had led to an internal explosion. The failure occurred inside the battery enclosure, which protected personnel from flying battery case particles and electrolyte. The electrolyte that spilled had drained from two holes in the base of the battery compartment.

The company involved has made the following recommendations:

  • Change out all batteries of sealed lead acid type annually.
  • Future permits to work (PTW) and maintenance procedures should take this incident into consideration, if jump starting or fault diagnosis is carried out with the battery exposed.

Latest Safety Flashes:

Fall from height during mooring due to rope tension reaction

Rope became entangled with the propellor during mooring operations of a tanker causing the operator to lose balance and fall onto the lower platform.

Read more
Missing protection – progressive wear on hydraulic hoses causes damage

During an inspection, several hydraulic hoses and fuel hoses were found in direct contact with surrounding surfaces and sharp edges.

Read more
Small engine room fire – flammable object ignited

While ramping up the starboard main engine, a small flammable foreign object ignited.

Read more
Positive: damage to Fast Rescue Craft davit wire rope caught before failure

During routine checks, it was observed that the FRC davit wire rope had a visible fracture at the socket termination area.

Read more
BSEE: Miscommunication and trapped pressure causes injury during valve maintenance

BSEE has published Safety Alert 509 relating to a gas release incident on an offshore platform.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.