LTI: Leg injury caused during HP water jetting

  • Safety Flash
  • Published on 3 May 2017
  • Generated on 11 April 2025
  • IMCA SF 09/17
  • 2 minute read
  • During diving operations to clean a riser with a high pressure (HP) water jet type Cavitek, a diver cut his leg (thigh) with the water jet.

What happened?

The incident occurred whilst the diver was not properly secured during the cleaning operation.

The diver should always be comfortably and securely positioned during HP water jetting operations. It is especially important to ensure that this is so during mid-water work, otherwise there is a greater likelihood that the diver may lose control of the trajectory of the jet stream during jetting operations. 

The likelihood of such an event will also be increased if the retro jet and forward jet on the gun is strongly unbalanced.

Cavitek type high pressure water jet

Cavitek type high pressure water jet

Our member notes that there was an incorrect calculation of the HP hose length needed for this job. The minimum length of hose required per jetting gun unit is normally considered to be 1.5 times the maximum anticipated working depth. The length of the hose should not impact upon the comfort and security of the diver during HP water jetting operations.

The length of the waterjet lance may not have been appropriate (too short). The inherent potential for accidental self-injury during use of high pressure jetting guns increases as the length of lance (barrel) decreases.

IMCA Code of practice for the use of high pressure jetting equipment by divers states that:

“Hoses should be tied off at convenient locations to assist in minimising movement due to pressure supply changes or tidal/current movement.

Hoses should never be tied off to any part of any diving equipment.”

Key lessons learned

  • Before water jetting operations:

    • Ensure proper and dedicated tool box talks are held.

    • Ensure there us a full assessment of risks and needs at the work area.

    • Check the required length of hose.

  • When cleaning vertical parts of structures in mid-water divers should be rigged to be stable and comfortable for jetting operations.

  • Check that the gun is appropriately designed, properly balanced, well-maintained and fit for purpose.

  • Ensure the diver holds the gun with two (2) hands.

  • Stop/release the trigger before each movement.

  • Ensure regular communication from the diver to the dive supervisor about the situation at depth.

Remind the dive team of the importance of good communications and consistent observance of safe working practices.

Latest Safety Flashes:

Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more
LTI: rope under tension moved and hit person’s hand

A member of the crew suffered a serious hand injury when struck by a rope under tension.

Read more
Injuries during lifting operations

A member reports two separate lifting activities involving failure of lifting equipment and resulting in minor injuries to nearby personnel.

Read more
Finger injury during manual handling

An IMCA’s members’ utilities supplier in the United States reports a serious finger injury during manual handling

Read more
Acetylene gas explosion

There was a small explosion and fire when crew were working on an oxy-acetylene system.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.