Crewman struck by dropped object

  • Safety Flash
  • Published on 4 June 2014
  • Generated on 1 April 2025
  • IMCA SF 08/14
  • 2 minute read

A member has reported a high potential incident in which a crewman was struck by a dropped object. 

What happened?

The incident occurred when the crewman was ascending a ladder to reach the access/egress of a scaffold platform, and he was struck on his right arm by a dropped object. After the object struck the person it fell down under the scaffold platform. The person looked up and saw another crewman standing on the scaffold platform receiving a bucket with scaffolding materials from further above. The bucket was being lowered on a rope from a windlass room.

The crewman descended the ladder to investigate the object that had struck him and found that it was a swivel coupler (scaffold material). He ‘stopped the job’, informed a nearby foreman, and asked other crewmen working in the vicinity of the tank if they had witnessed the incident; unfortunately no one saw exactly what happened, and therefore the origin of the dropped swivel is unknown. The foreman made a fresh visual risk assessment of the scene which included proper housekeeping (swivels stored on the boards next to gate/access) and discussion of the potential consequences of dropped objects. The importance of using correct lifting equipment (in this case, soft scaffolding lift sacks) rather than buckets was reinforced.

The crewman reported to the medic for a medical check-up which revealed no injuries.

Showing worksite at time of incident

Showing worksite at time of incident

Swivel coupler

Swivel coupler

Illustrating buckets (wrong) and soft-sided sacks (better) for lifting

Illustrating buckets (wrong) and soft-sided sacks (better) for lifting

Our member’s investigation revealed the following:

  • The origin of the swivel could have been: – A swivel fell from the bucket – A swivel laying on the scaffold board fell. (Possibly kicked but unlikely due to kick plate and gate) – While emptying the bucket a swivel bounced and fell.
  • Direct cause:
    • Improper lifting, handling or storage -improper lifting equipment was used to transport the scaffolding materials down (buckets attached to approximately 20 metre rope).
    • Poor housekeeping -some swivels were left behind next to the access gate near the ladder.
  • Root cause:
    • Improper handling of materials -lowering scaffold materials (approximately 20m) down from height with buckets attached to a rope.
    • Improper storage of materials -The temporary stored swivel couplers were stored too close to the ladder access/entrance of the platform.

Members may also find useful information from dropsonline.com

Latest Safety Flashes:

LTI: rope under tension moved and hit person’s hand

A member of the crew suffered a serious hand injury when struck by a rope under tension.

Read more
Injuries during lifting operations

A member reports two separate lifting activities involving failure of lifting equipment and resulting in minor injuries to nearby personnel.

Read more
Finger injury during manual handling

An IMCA’s members’ utilities supplier in the United States reports a serious finger injury during manual handling

Read more
Acetylene gas explosion

There was a small explosion and fire when crew were working on an oxy-acetylene system.

Read more
Crane cab fire caused by fridge

On a vessel alongside, there was a fire in the cab of a crane.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.