Fatality after capsize of workboat with eight persons onboard
- Safety Flash
- Published on 27 July 2011
- Generated on 18 April 2025
- IMCA SF 08/11
- 4 minute read
Jump to:
A Member has reported an incident in which a workboat capsized during personnel transfer, causing seven people to fall into the sea, one of whom drowned.
What happened?
The workboat was transferring personnel from a vessel to a cargo barge during the hours of darkness. Weather conditions were: Wind E 16 knots; Sea state 0.7m-1.3m with period 3.8s, which conditions were considered by the member to be within acceptable parameters for this kind of operation.
The workboat approached the cargo barge from the stern portside. One person disembarked the workboat onto the cargo barge. Immediately after this, the workboat was hit by two waves from the port side; the first filling it with water and the second causing it to capsize. The person who disembarked raised the alarm by radio. Two members of the crew climbed onto the hull of the capsized workboat and unsuccessfully attempted to right the boat by operating the manual handle to the self-righting gear. The other five persons made their way to the polypropylene rope attached to the emergency tow wire located on the stern port side of the cargo barge. Of these five persons, three did not hold on and drifted away, the deceased being one of them. The other two were recovered safely onto the cargo barge. A tug vessel present in the area, closest to the cargo barge, was requested to search for and recover the lost personnel. This tug recovered the two crew members from the hull of the capsized workboat, and two crew members from the water who had been holding onto the polypropylene rope. The third missing crew member was recovered later by a supply vessel in the area but was already dead.

cargo barge

workboat used
What were the causes?
Investigation revealed that:
- The problem had not been anticipated; the capsizing of this type of workboat had never occurred previously.
- The workboat had frequently been utilised in the same sea conditions including operations during the hours of darkness.
- Maintenance and inspection of the workboats was not fully in line with International Convention for the Safety of Life at Sea (SOLAS) requirements.
- Inspection of the self-righting gear revealed that the safety pin utilised to prevent activation during transportation had never been removed. Inspection of the records of the workboat manual revealed that no reference was made to this device or that it should be removed before use at sea.
- Emergency response was not adequate; thus, the full detail of the emergency was not understood by those responsible for initiating the relevant response action.
- Vessel man overboard procedures did not cover overboard scenarios remote from the vessel. Man overboard drills and exercises were limited to loss overboard from main vessel and did not consider personnel working in remote locations.
Actions
The following corrective actions were suggested:
- Ensure that a backup vessel is always present during vessel to vessel personnel transfer.
- Ensure that workboat personnel have specific personal protective equipment (PPE) for transfer operations dependent on local climate and conditions, including personal locator beacons, life-jackets, waterproof radios, work suits as appropriate, and appropriate headgear.
- Ensure that during the hours of darkness the bridge watchman has access to night vision binoculars.
- Review procedure for personnel transfer, to include clear line of command and who should authorise the launching of a workboat.
- Develop drills and exercises for man overboard scenario remote from vessel.
- Amend planned maintenance schedule to include checks of self-righting gear and develop user checklist.
- Ensure boarding arrangements on barges are properly considered before use; consider the possibility of development of improved or appropriate boat landing access on barges.
- Ensure adequate lighting is available on cargo barges.
- Identify appropriate tracking system for workboats.
- Investigate the use of alternate means of personnel transfer.
Members are reminded that IMCA has published Guidance on the transfer of personnel to and from offshore vessels and structures.
IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.
The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.
All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.
IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.
The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.
Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.