Technical Service Bulletin from Broco/Rankin – BR22 Plus Exothermic Cutting Torch

  • Safety Flash
  • Published on 22 March 2018
  • Generated on 22 February 2025
  • IMCA SF 07/18
  • 1 minute read

The Association of Diving Contractors International (ADCI) has circulated an updated Technical Service Bulletin from Broco/Rankin relating to the BR22 Plus Exothermic Cutting Torch. This was sent out by Broco/Rankin on 13 March 2018.

The bulletin, available here, notes that “a recent report of an external oxygen leak from the control valve of a BR22 PLUS prompted an investigation to determine root cause. The result of that investigation concluded that machining debris in the O-ring groove of the Control Valve Nut has interfered with the Oxygen seal in the valve assembly“.

Members using this equipment should download and read the bulletin, and take the actions recommended therein.

Leak Test Procedure

BR22 Plus Torch

This picture shows what a BR22 PLUS torch looks like and the location of the valve stem leak. If this is not what your torch looks like, do not continue!

BR22 Plus Torch

Outfit the BR22 PLUS torch as shown with an 18″ cutting rod inserted and the collet tightened

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.