MAIB: Fatal accident during cargo operations on Karina C

  • Safety Flash
  • Published on 19 February 2021
  • Generated on 22 February 2025
  • IMCA SF 06/21
  • 3 minute read

The UK Marine Accident Investigation Branch (MAIB) has published accident its investigation report into a fatal crush incident during lifting operations on the general cargo vessel Karina C on 24 May 2019. See here for details: www.gov.uk/government/news/karina-c-report-published.

What happened?

The second officer of the general cargo vessel Karina C was fatally injured when he was crushed between the vessel’s gantry crane and a stack of cargo hold hatch covers during post-cargo loading operations.

The second officer had been working at the aft end of the main deck and was attempting to pass between the hatch covers and the stationary crane. As the second officer climbed onto the hatch coaming, the vessel’s chief officer drove the crane aft, trapping and crushing the second officer against the hatch covers. The chief officer immediately reversed the crane and the second officer fell onto the deck, where he received first-aid and cardiopulmonary resuscitation from the deck crew and shore paramedics.

The UK Marine Accident Investigation Branch (MAIB) has published accident its investigation report into a fatal crush incident during lifting operations on the general cargo vessel Karina C on 24 May 2019

An emergency services doctor, who was informed that the second officer had fallen from the hatch coaming onto the deck, told the crew that the second officer probably died after having a heart attack.  Based on the doctor’s initial assumption and the evidence provided by the vessel’s crew, the accident was not reported to the MAIB.  

Only following receipt of the second officer’s postmortem report and close examination of Karina C’s closed-circuit television recordings was the incident reported by the vessel management to the MAIB.  The accident occurred on the second officer’s birthday and the postmortem toxicology report showed that he had a significant quantity of alcohol in his bloodstream.

What went wrong?

The investigation concluded that:

  • Deck operations were not being properly controlled or supervised and the deck officers did not communicate with each other – the second officer did not know the chief officer was about to move the crane and the chief officer did not know where the second officer was, or what he intended to do.

  • The second officer’s judgement and perception of risk were probably adversely affected by alcohol.

  • Tiredness might also have adversely influenced the second officer’s actions.

  • The master did not adequately investigate or report the accident.

  • The safety culture on board was weak; company procedures were not followed, and several unsafe working practices were observed.

  • The company’s drug and alcohol policy was not being enforced.

Members may wish to refer to:

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.