Confined space – multiple fatalities

  • Safety Flash
  • Published on 14 July 2011
  • Generated on 24 April 2025
  • IMCA SF 06/11
  • 2 minute read

IMCA has received information about a confined space incident in which there were multiple fatalities.

What happened?

The incident occurred at an oil well on land.

A workman entered a water tank that contained water mixed with nitrogen, and collapsed.

A co-worker entered after him in an attempt to rescue him, and likewise collapsed.

He was followed by two further workers who also collapsed.

Image1 (5)

the water tank where incident occurred

The supervisor realised that four workers were inside the tank, gave orders to drain the tank and then asked two further personnel to enter the tank for rescue purposes using safety lines.

Three of the rescued personnel were found unconscious and one semi-conscious. All four were evacuated to a nearby clinic for first aid and then to hospital for further treatment.

The three men found unconscious did not recover and were declared dead by a local doctor.

What were the causes?

Investigation revealed that:

  • Procedures were not followed.

  • There was no permit to work for confined space entry arranged in this case.

  • There were no multi-gas tests conducted (LEL, O2, CO2‚ and H2S) before confined space entry.

  • Personnel did not wear appropriate personal protective equipment (PPE) for task.

  • The rescue attempt was not properly planned or thought through.

Reminder

IMCA has dealt with both confined spaces and permits to work in the following pocket safety cards:

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.