Fire in vertical lay system moonpool

  • Safety Flash
  • Published on 22 April 2009
  • Generated on 22 February 2025
  • IMCA SF 05/09
  • 3 minute read

A Member has reported an incident in which there was a fire in the moonpool of a vertical lay system (VLS). 

What happened?

A vessel had been involved with the recovery of redundant/damaged 10″ flexible flowlines to on-deck storage reels, and ‘wet storage’ (on the seabed) was being prepared for a previously recovered section of 10″ flowline. (This flowline section had been flushed of hydrocarbons in January 2008.)

Following the recovery of the flowlines to deck, the vessel made several transits totalling approximately 12 kilometres over a 19 hour period. Work was approved to remove some gouges on the VLS moonpool doors utilising a pneumatic grinder. A highly experienced, and competent, boilermaker proceeded to grind out the gouges on the moonpool doors with the grinding sparks directed down and into the moonpool water.

A fire started on the water within the moonpool centraliser and then grew to an above deck height of more than two metres. The person conducting the grinding was using body harness/fall arrest equipment as the moonpool doors had been opened slightly to give him better access. When the fire started, he experienced difficulty in escaping from the area as the fall arrest unit prevented the pay-out of the cable. Fortunately a nearby colleague freed him from the fall arrest cable and they both escaped from the fire area without injury.

The fire alarm was raised and the fire was extinguished within 25 minutes of the alarm being sounded with no persons injured or harmed.

What were the causes?

The following were noted:

  • The moonpool area, including the area below the VLS doors, was visually checked prior to the grinding, but nevertheless nobody observed or identified the presence of flammable liquids within the moonpool.

  • At the earlier onshore hazard identification and risk assessment, the presence of ‘inhibited seawater’ containing very low hydrocarbon levels had been identified, however a fire risk or accumulation of flammable hydrocarbon products within the confines of the moonpool had not been considered as a potential hazard.

  • The concentration of hydrocarbon levels found within the 10″ flowline was inconsistent with the hydrocarbon levels expected (‘flushing fluid’ consisting of hydrocarbon < 30 mg/ltr (flushed earlier in 2008)). It is possible that there may have been localised concentration of oil in the intervening period through gravity separation of fluids of different densities and/or reintegration of oil trapped in the interstices of the rough bore pipe carcass.

  • The application of the permit to work, risk assessment and associated process were not sufficiently robust or effective and several management system improvements have been identified/implemented.

  • Competency of the onboard personnel resulted in the fire teams responding very quickly and bringing the fire under control in a timely manner.

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.