Loose bolts on turbine engine exhaust stack

  • Safety Flash
  • Published on 1 May 1999
  • Generated on 22 February 2025
  • IMCA SF 03/99
  • 1 minute read

The following near miss on an offshore installation has been reported.

What happened?

During high winds a 21m exhaust slack from one of the turbine engines on an offshore installation was seen to be moved abnormally. It appeared that the point of movement was at a joint halfway up the stack. Concerned that the top section might fall off, the installation was shut down and depressurised.

 

Our member’s investigation revealed the following:

When scaffolding was erected and lagging removed, all 64 bolts around the joint were found to be loose and many bolts had come off – this is assumed to be due to vibration. It transpired that this part of the stack installed ten years ago had not been inspected since, while other parts of the stack were included on the maintenance schedule. Also the bolts used were not the ones specified in the design. These have since been replaced with bolts with a locking nut to prevent them from loosening during service.

Recommendations

This near miss highlights the need for inaccessible joints to be included in planned maintenance routines.

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.