Transponder pressure relief system failure

  • Safety Flash
  • Published on 1 March 2005
  • Generated on 22 February 2025
  • IMCA SF 03/05
  • 1 minute read

Whilst reviewing its test and repair procedures for transponders, a member has reported that a serious flaw was discovered in the pressure relief mechanism in two out of three Kongsberg transponders tested. 

Such transponders are in common use across marine operations world-wide and it is possible that some could exhibit the same fault whereby internal pressure build-up would not be able to be vented automatically.

It appeared that the pressure relief mechanism was locked in place and would not operate, possibly due to an assembly fault by the manufacturer.

Pending detailed instructions from the manufacturer, the contractor instructed its personnel not to disassemble any such transponders.

Kongsberg has been exploring the matter, relating to the RPT model transponder (which went out of production in 2002) and has now issued a technical bulletin on the subject, a copy of which is attached below.

Safety Flash 03 05 3
Safety Flash 03 05 4
Safety Flash 03 05 5
Safety Flash 03 05 6

Latest Safety Flashes:

Crew transfer vessel (CTV) drifts onto turbine tower

A CTV drifted into and hit a nearby structure at 0.5 knots.

Read more
LTI: Fall from height during FRC maintenance

A worker fell 2.3 m to deck from a small boat in the davit, and broke a leg as a result. 

Read more
Near miss: narrowly avoided fall from height due to missing deck gratings

After a grating was removed, the Chief Engineer, on the way to inspect the work, nearly fell 4-5m.

Read more
MSF: A broken stretcher could have led to injury

The Marine Safety Forum (MSF) published Safety Alert 24-09 relating to a broken stretcher.

Read more
Positive story: Excellent galley hygiene and housekeeping

On a walk-around audit, a member highlights very high standards of housekeeping and hygiene in the galley on one of its vessels.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.