Secured material fell against crewman causing injury

  • Safety Flash
  • Published on 5 January 2021
  • Generated on 20 October 2026
  • IMCA SF 02/21
  • 3 minute read

A crewman was injured when a stack of assorted sheet metal and wood fell against him. 

What happened?

The incident occurred when he was performing a safety walk round in preparation for a period of rough weather. He identified that the material was not secured sufficiently; it was seen to be rocking against the vessel’s superstructure. This material had previously been stored in an area without any protection from outside environmental conditions. It had been decided some 6 months previously, to move it to its present position, a covered passageway.

What went wrong

The sheets of material were secured with two webbing cargo ratchet straps hooked onto the surrounding ship’s superstructure. In the process of removing slack from one of the webbing straps, the other loosened, resulting in both straps disengaging. At that point, movement of the vessel caused the unsecured rack to fall towards the crewman. He was unable to prevent the rack from falling on him and became pinned under the sheet material with most of the weight being taken on his right thigh.  He called for help from a nearby colleague and was rescued. The following day he was able to visit a hospital ashore for X-rays to his leg, where no fractures of bones were detected, and he returned to his duties on board.

Old storage arrangements

Old storage arrangements

location of injured person

location of injured person

Improved storage arrangmements

Improved storage arrangmements

swipe to see next image.

Lessons learned/actions taken

  • Storage of such material:

    • Ensure appropriate risk assessment is developed.

    • Consider whether or not sheet material, particularly metal, needs to be stored onboard.

    • Develop new and improved safer securing arrangements.

Our member took this as an opportunity for discussion at toolbox talks, including the following:

  • Lone working should be discussed during start of shift/task toolbox talks, and crew should seek help from colleagues when necessary.

  • How is change managed during a task, particularly with respect to worsening weather at sea, and most especially during lifting operations.

  • How can we improve our toolbox talks:

    • When should we hold a toolbox talk? E.g. before start of routine or only higher risk/non-routine tasks?

    • A routine operation may become non-routine due to a very small change, with new risks being introduced.

    • A toolbox talk or meeting before a routine task is an opportunity to discuss the individual steps within an operation and where there things could change from the routine. When these changes are identified, any possible new risks can be discussed, and plans put in place for mitigation.  Further to this, a toolbox talk may be held when change from the planned or routine has occurred during an operation.

Members may wish to refer to:

Latest Safety Flashes:

Hydraulic oil leak detected below moonpool

A hydraulic oil leak was identified below the moonpool after the worktable doors were opened.

Read more
Dropped scaffold board (kickplate) – SIF near miss

A scaffolding kickboard was accidentally dropped falling from a height of 6.5 metres to the main deck.

Read more
H₂S detected on deck

During vessel transit back to port, Hydrogen Sulphide (H₂S) was detected in the open space on the main deck.

Read more
Restoration and verification after maintenance

A missing flooring panel was identified beneath a 415V bow thruster electrical motor cabinet.

Read more
Vessel contact during materiel transfer in adverse weather

One vessel lost heading and position control because of the strong winds and swell, pushing it toward another.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.