Near-miss: improper use of fall-arrest equipment leads to fall

  • Safety Flash
  • Published on 8 April 2010
  • Generated on 28 April 2025
  • IMCA SF 02/10
  • 3 minute read

A Member has reported an incident in which a rigger fell approximately one metre into the sea during rope access work. 

What happened?

The rigger was able to climb back up to the fairlead access platform opening. There were no injuries and no emergency rescue was required.

Two riggers were required to remove the pennant wire and clamp from an anchor wire so that recovery of the anchor could continue. The task involved rope access and positioning from the outboard railing using a fairlead access opening to a working platform in order to reach the clamp and pennant wire socket connection (shackle).

The rope access attachment was a ‘shark hook’ and strop configuration. One rigger selected a strop that provided movement of the connection point so the anchorage point would be under vertical tension. The other rigger selected a shorter strop and one designed to wrap around beams that may have sharp corners. This strop incorporated a one sided rubber liner to protect the integrity of the strop material which also prevented free movement. The final arrangement on this strop had the triangular D-ring adjacent to the choked position. This beam strop and rope access connection was completed from the inboard deck space and not adjusted to the outboard position in a direct line of tension, as should have been done, and the strop was unable to slide around into an ideal position. The rigger using this configuration was applying pressure to the rope access equipment to a position opposite the other rigger, when his shark hook and strop D-ring disconnected causing him to slip approximately one metre into the water.

During the company’s investigation the following points were noted:

  • An incompatible strop/connector was selected and used as an attachment point (choked around outboard railing). This should not have been permitted.
  • The rigger did not check the double action connection was engaged and under vertical tension prior to descending into position.
  • There was no dedicated spotter.
  • The lanyard connector and anchor point set up enabled ‘roll out’ to occur through side loading on the primary locking device.
  • No secondary safety line was used.
shark hook’ and strop configuration
shark hook’ and strop configuration
shark hook’ and strop configuration

Swipe to see next image

The company made the following actions and recommendations:

  • The type of strop and descending device was changed out before work continued.
  • Personnel were briefed on principles of ‘dynamic roll-out’ and the correct selection of rope access, anchorage points and fall restraint equipment.
  • Specialist equipment for ‘over the side’ work should be purchased as a matched set, clearly identified, inspected and kept together at all times for specific ‘over the side’ tasks.
  • Working at heights awareness training should be a prerequisite for any task requiring the use of fall restraint equipment. Training in rescue equipment and techniques should also be a minimum standard for spotters.

Latest Safety Flashes:

Fatality following a fall from a wind turbine

The Scottish Courts and Tribunals Service, and UK HSE, has published a response to a fatal incident in which a crew member fell to their death.

Read more
UK HSE: Risk of collision with offshore installations from attendant vessels

The UK Health and Safety Executive (HSE) has published Safety Notice ED01-2025 relating to the risk of collision with offshore installations.

Read more
USCG: Hazardous Zone Markings and Safety Protocol Awareness

The United States Coastguard has published Safety Alert 04-25 relating to the importance of Hazardous Zone Markings and Safety Protocol Awareness.

Read more
BSEE: Crane safety awareness during offshore helideck operations

BSEE published Safety Alert 491 relating to a the investigation of a near miss crane incident on an offshore platform.

Read more
Incidents occurring during decommissioning

IMCA has put together a summary of incidents relating to decommissioning.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.