Lacerated wound and fracture of the knee

  • Safety Flash
  • Published on 1 January 2002
  • Generated on 28 November 2026
  • IMCA SF 01/02
  • 2 minute read

We have been notified of the following incident in the drilling sector.

What happened?

An assistant driller and others were trying to lift the balancing frame to ‘guide line’ with the aid of a tugger winch, so that it could be lowered to the well head. Because the frame winch wasn’t in a proper balance position, the assistant driller tried to adjust the sling for lifting. When he had just finished shackling the frame to the winch sling, the balancing frame fell backward onto his right knee. The photos allow a better understanding of the accident.

Balancing frame
Fallen balancing frame

The injured person had not observed that there was no tension on the sling that he shackled to the frame before carrying out the adjustment on the sling. He probably failed to signal to the winch operator to pick up and tension the sling.

The assistant driller suffered a lacerated wound on the lateral side of his right leg and a fracture of the knee.

The company involved has noted the following corrective actions:

  • Riggers on board to be properly trained.
  • Activity to be planned with proper toolbox meetings and job safety analysis, as this helps avoid this kind of incident occurring in the future.
  • Improve communication between operator involved in the operation.

Latest Safety Flashes:

LTI: serious finger injuries during crane operations

The boom of a 12 tonne crane moved towards the pipelay tower, and trapped the spotter’s left hand against a handrail. 

Read more
Finger injury caused during maintenance of rotating machinery

Although the electrical supply was isolated, a V-belt continued to rotate due to residual mechanical energy.

Read more
MSF: Serious hand injury (LTI) – failure to Isolate

Chief Engineer attempted to adjust an air filter housing clamp, and his hand entered the exposed hazard zone, contacting the rotating turbocharger fan.

Read more
MSF: Someone’s finger trapped in the door

The Marine Safety Forum (MSF) has published Safety Alert 26-15 relating to a finger caught in a door.

Read more
Hand injuries - keep your hands clear, every task, every time

One of our Members notes a spate of recent hand injuries occurring during multiple activities.

Read more

IMCA Safety Flashes summarise key safety matters and incidents, allowing lessons to be more easily learnt for the benefit of the entire offshore industry.

The effectiveness of the IMCA Safety Flash system depends on the industry sharing information and so avoiding repeat incidents. Incidents are classified according to IOGP's Life Saving Rules.

All information is anonymised or sanitised, as appropriate, and warnings for graphic content included where possible.

IMCA makes every effort to ensure both the accuracy and reliability of the information shared, but is not be liable for any guidance and/or recommendation and/or statement herein contained.

The information contained in this document does not fulfil or replace any individual's or Member's legal, regulatory or other duties or obligations in respect of their operations. Individuals and Members remain solely responsible for the safe, lawful and proper conduct of their operations.

Share your safety incidents with IMCA online. Sign-up to receive Safety Flashes straight to your email.